13.3.29 73:Ax2braketest
Triggering
Level
Response
Fault counter
For active brake management
in the SDS 5000, the time set in
B311
has elapsed without the
B300 Brake test
action with
active axis 2 having been
performed.
Cause 1 and 2: Fault, Cause 3:
Message
This fault only occurs with the enable switched off.
Z73
Cause
Description
Measure
Acknowledgement
1:B311Timeout
The time entered in
B311 Timeout for
brake test B300
has elapsed twice
without the
B300 Brake test
action with
active axis 2 having been performed.
Perform the
B300 brake test
action.
For the
Fault
level, the event can
be acknowledged for a duration
of 5 minutes to be able to
perform the
B300 brake test
action. If this time elapses
without the
B300 Brake test
with
active axis 2 being successfully
performed, the inverter changes
to the
Malfunction
state again. If
the
B300 brake test
action is
successfully performed, the
event is automatically
acknowledged.
2:Brake defective
When performing the brake test action
with active axis 2, the holding torque
entered in
B304
or
B305
could not be
applied or the encoder test run included
in the brake test was completed with
errors.
•
Perform the brake grinding function
and then the brake test.
•
Replace the motor.
3:Brake test required
Timeout for brake test has elapsed once
without the test brake action being
performed.
Perform the action
B300
test brake.