Parameterizing encoder data
ID 442289.06
46
Operation manual POSIDYN® SDS 5000
6
WE
KEEP
THINGS
MOVING
6.5
Interface X140
You can connect the following encoders to X140:
•
Resolver
•
Absolute value encoder EnDat 2.1 sin/cos
You will need the this option when you use the X140 interface:
•
REA 5001
Parameterize interface X140
1. Open the configuration assistant and select step 6.
2. In option 2, enter the selection REA 5001 and make sure that the option is actually installed on the
inverter and correctly connected.
3. Exit the configuration assistant.
4. In
B26
, enter
3:X140-encoder
.
5. In
H140
set the encoder system which you want to run on X140.
6. Set
H142
and
H148
in accordance with the connected encoder.
7. Transfer the settings to the inverter and save them.
8. Switch the inverter off and back on again.
You have parameterized interface X140.