Integrated Bus
Operation manual POSIDYN® SDS 5000
ID 442289.06
WE
KEEP
THINGS
MOVING
79
11
11.2.6
Reading data from the SDS 5000
You must have established a direct connection before you can read data from an SDS 5000. After you have
done this, proceed as shown below:
The
Read configuration / parameters from IGB
dialog screen also offers the function of assigning inverters to
the inverter entry based on the resources identifier (
Allocation 1:1 as per resources button
). This requires the
entry of an unambiguous resource identifier. This button is particularly useful when changes must be made to
an already existing project. The resource identifier is entered in the configuration assistant in step 1. You can
also make changes in the Project view by clicking the related inverter with the right mouse button. In the
context menu which appears, select the item
Rename inverter
. In the next dialog screen that appears, you
can make the changes.
When you click the
Read all
button in the
Read configuration / Parameters from IGB
dialog screen, all
inverters are read and the data are indicated in POSITool as new inverter entries.
Reading data from the SDS 5000
1. In the
IGB
:
display connected
devices dialog screen, click the
read from IGB…
button.
The following dialog screen appears:
In the first column of this dialog screen, you can select the inverters which are connected to the PC.
The possible targets in your project are shown in the second column.
2. Highlight the line of the inverter entry in POSITool to which the data are to be written. You can select an
already existing inverter entry
(
I1: Inverter1
) or set up a new inverter entry (
new
).
3. In this line, double click the first column
Source
(
IGB
) (
<Please select>
).
A selection list appears showing all inverters which are connected to the PC.
4. Select the inverter whose data you want to read.
5. Repeat steps 2 to 4 for each source to be read from.
6. Click the
OK
button.
The data are loaded as you specified and shown in POSITool.