Diagnosis
ID 442289.06
192
Operation manual POSIDYN® SDS 5000
13
WE
KEEP
THINGS
MOVING
13.3.50 no configuration paramodul error
When displaying
no configuration paramodule error
, the device start-up is ended and an error was detected
by the Paramodule during start-up. Note also the events in section 13.3.37 *ParaModul ERROR:update
firmware! to 13.3.40 *ParaModul ERROR: ksb write error. Alternating to the event display, STÖBER
ANTRIEBSTECHNIK appears.
13.3.51 no configuration start error
When displaying
no configuration start error
, the device start-up is ended and an error was detected when
starting the configuration. Note also the events in section 13.3.41 *ConfigStartERROR parameters lost to
13.3.49 *ConfigStartERROR unknown hiding. Alternating to the event display, STÖBER ANTRIEBSTECHNIK
appears.
13.3.52 configuration stopped
When displaying
configuration stopped
, the current configuration was stopped. Apply a configuration or switch
the inverter off and on again so that the previous configuration can be loaded from the Paramodule.