Parameterizing brake data
Operation manual POSIDYN® SDS 5000
ID 442289.06
WE
KEEP
THINGS
MOVING
47
7
7
Parameterizing brake data
Motors with holding brakes can be connected to the devices oft the 5
th
generation of STOBER inverters. There
are two ways to activate the brake.
A brake control is integrated in the following applications:
•
Fast reference value with brake activation
•
Comfort reference value
•
Technology controller
•
Command positioning (endless and limited position range)
•
Synchronous command positioning (endless and limited position range)
•
Motion block positioning (endless and limited position range)
•
Electronic cam (endless and limited position range)
You can activate the brake control in parameter
F08
. Further adjustments are made depending on the
selected control mode.
In addition, a signal source can be parameterized in
F100
. The signal for releasing the brake can be given
direct via the source.
F100
is a global parameter and is available in every application.
If
F08
is set to
0:inactive
, the brake is activated together with system enable
A900
. In this case, the brake
release times and brake application times are ignored.
In the
F08 = 1:active
setting, the current motor torque is saved when the brake is applied. This torque is
applied again when the brake is released. If
F08
is set to
2:Do not save torque
, only the motor magnetization
is established when the brake is released.
As the brake controller parameterization depends on the selected control mode, the following sections are
subdivided accordingly.