Integrated Bus
Operation manual POSIDYN® SDS 5000
ID 442289.06
WE
KEEP
THINGS
MOVING
115
11
The
error category
stands for a group of errors:
The
Error value
specifies the error in an error category. The error values are specified for each error category
in the following.
In error category 00 hex, the error value is always 00
hex
.
The following errors can occur in error category 01
hex
:
The cause of these errors can be a faulty TCP/IP connection. Check the connection and the network settings.
The TCP/IP connection may also be blocked by a firewall. Check (e.g., with POSITool) whether the Teleserver
can be reached.
The following errors can occur in error category 02
hex
:
Error category
Description
00
hex
No remote maintenance is active or no error occurred.
01
hex
A socket error was determined (problems with the use of the TCP/IP connection).
02
hex
A firmware error was determined (internal firmware error).
03
hex
An HTTP error was determined (problems at the HTTP communication level).
04
hex
A TCP/IP error was determined (problems at the TCP/IP communication level).
05
hex
An error of the Teleserver Client application was determined.
06
hex
A DNS error was determined (problems with the DNS resolver).
07
hex
A proxy error was determined (problems with the proxy settings).
Error value
Description
00
hex
Reserved
01
hex
A TCP/IP error occurred during sending or receiving.
02
hex
A TCP/IP error occurred during sending or receiving.
Error value
Description
00
hex
Reserved
01
hex
Internal error 1
02
hex
Too little free memory space available.
03
hex
An internal handle is invalid.
04
hex
An error occurred while the HTTP application was being executed.
05
hex
An internal parameter is invalid.
06
hex
An internal parameter is invalid.
07
hex
An internal parameter is invalid.
08
hex
Too little free memory space available.
09
hex
Too little free memory space available.
0A
hex
Too little free memory space available.