Flexible static memory controller (FSMC)
RM0008
540/1096
Doc ID 13902 Rev 12
ECC result registers 2/3 (FSMC_ECCR2/3)
Address offset: 0xA000 0000 + 0x54 + 0x20 * (x – 1), x = 2 or 3
Reset value: 0x0000 0000
These registers contain the current error correction code value computed by the ECC
computation modules of the FSMC controller (one module per NAND Flash memory bank).
When the CPU reads the data from a NAND Flash memory page at the correct address
(refer to
Section 21.6.6: Error correction code computation ECC (NAND Flash)
), the data
read from or written to the NAND Flash are processed automatically by ECC computation
module. At the end of X bytes read (according to the ECCPS field in the FSMC_PCRx
registers), the CPU must read the computed ECC value from the FSMC_ECCx registers,
and then verify whether these computed parity data are the same as the parity value
recorded in the spare area, to determine whether a page is valid, and, to correct it if
applicable. The FSMC_ECCRx registers should be cleared after being read by setting the
ECCEN bit to zero. For computing a new data block, the ECCEN bit must be set to one.
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
ECCx
r
Bits 31:0
ECCx:
ECC result
This field provides the value computed by the ECC computation logic.
hereafter
describes the contents of these bit fields.
Table 134.
ECC result relevant bits
ECCPS[2:0]
Page size in bytes
ECC bits
000
256
ECC[21:0]
001
512
ECC[23:0]
010
1024
ECC[25:0]
011
2048
ECC[27:0]
100
4096
ECC[29:0]
101
8192
ECC[31:0]