2-3
PDW-HD1500/V1 (E)
2-2-1. Error 0X
When errors related to optical drive control or to devices are detected, the following error codes are
displayed.
Main
Sub
Time data
Maintenance
Drive
Description
code
code
display
logger
logger
02
020
←
O
O
Optical block assembly (OP0) (referred to as OP hereafter) is recording at
maximum laser output.
Perform the pickup lens cleaning. (Refer to Section 4-7-16.)
0A0
←
O
O
Optical block assembly (OP1) (referred to as OP hereafter) is recording at
maximum laser output.
Perform the pickup lens cleaning. (Refer to Section 4-7-16.)
F2E
←
O
O
OP laser is determined to be deteriorated in the laser deterioration assess-
ment for OP (OP0).
F37
←
O
O
No movement is detected in the ND filter initial operation check of OP (OP0).
FAE
←
O
O
OP laser is determined to be deteriorated in the laser deterioration assess-
ment for OP (OP1).
FB7
←
O
O
No movement is detected in the ND filter initial operation check of OP (OP1).
X25
←
O
O
OP (OP0) laser output error is detected.
X26
←
O
O
OP (OP0) laser output coefficient cannot be adjusted.
X27
←
O
O
OP (OP0) laser current is abnormal (zero or excessive).
X28
←
O
O
OP laser output is stopped judging that no cartridge is inserted.
X37
←
O
O
OP (OP0) ND filter setting cannot be changed.
XA5
←
O
O
OP (OP1) laser output error is detected.
XA6
←
O
O
OP (OP1) laser output coefficient cannot be adjusted.
XA7
←
O
O
OP (OP1) laser current is abnormal (zero or excessive).
XB7
←
O
O
OP (OP1) ND filter setting cannot be changed.
03
060
←
X
O
OP (OP0) tracking servo is frequently down.
0E0
←
X
O
OP (OP1) tracking servo is frequently down.
X54
←
O
O
No signal from disc required for OP (OP0) focus servo can be detected.
X57
←
O
O
No control current is detected in OP (OP0) focus servo.
X58
←
O
O
Excessive control current is detected in OP(OP0) focus servo.
X67
←
O
O
No control current is detected in OP (OP0) tracking servo.
X68
←
O
O
Excessive control current is detected in OP (OP0) tracking servo.
XD4
←
O
O
No signal from disc required for OP (OP1) focus servo can be detected.
XD7
←
O
O
No control current is detected in OP (OP1) focus servo.
XD8
←
O
O
Excessive control current is detected in OP(OP1) focus servo.
XE7
←
O
O
No control current is detected in OP (OP1) tracking servo.
XE8
←
O
O
Excessive control current is detected in OP (OP1) tracking servo.
04
X7C
←
O
O
OP (OP0) cannot move to disc’s innermost circumference.
X7D
←
O
O
OP (OP0) cannot move to disc’s outermost circumference.
XFC
←
O
O
OP (OP1) cannot move to disc’s innermost circumference.
XFD
←
O
O
OP (OP1) cannot move to disc’s outermost circumference.
(Continue)
Содержание XDCAM PDW-HD1500
Страница 29: ...1 21 PDW HD1500 V1 E HD video outputs 75 Color Bars Black SD video outputs 75 Color Bars Black ...
Страница 36: ......
Страница 46: ......
Страница 94: ......
Страница 158: ......
Страница 160: ...Printed in Japan Sony Corporation 2009 6 16 2008 PDW HD1500 SY PDW HD1500 CN E 9 968 423 04 ...