1-9
PDW-HD1500/V1 (E)
Screw with drop-safe
Flexible card wire
SE-852 board
CN1
Loader (P200)
assembly
Spindle motor
Top view
A
Right side rib
Left side rib
8. While pushing the lock arm in the direction of the
arrow, take out the cartridge from the loader (P200)
assembly.
m
.
Do not touch the disc surface.
.
To installing the loader (P200) assembly, refer to
“6-3. Replacing Loader Assembly”.
Loader (P200)
assembly
Lock arm
Cartridge
Disc surface
5. Release the lock by sliding portion A of connector
CN1 on the SE-852 board as shown in the figure with
tweezers or another tool, and disconnect the flexible
card wire.
m
.
Life of flexible card wire will be significantly
shortened if it is folded. Be very careful not to fold
it.
.
When reinstalling the removed parts, be careful not
to break the locking claws of the connector CN1 of
the SE-852 board.
6. Loosen the two screws with drop-safe on the loader
(P200) assembly.
7. Remove the loader (P200) assembly from the rear side
in the direction of the arrow.
m
.
Stepped shafts are inserted into the loader (P200)
assembly on both sides of the front. Remove the
loader (P200) assembly after slightly pulling it
toward the rear.
.
The spindle motor has an intense powerful magnet.
A part of the loader (P200) assembly may be
attracted by the magnetic force or hooked on the
edge of the spindle motor. Be careful when remov-
ing the loader (P200) assembly.