5-2
PDW-HD1500/V1 (E)
Display contents
Menu No.
Menu Display
Item
Contents
H11
OPE HOURS
Operation hours
Total operation hours (Resettable)
H12
LASER0
Laser parameter 0 Total output hours of laser on optical block assembly (OP0) (Resettable)
H13
SEEK HOURS0
Seek running 0
Total running hours of seek on optical block assembly (OP0) (Resettable)
H14
SPDL HOURS
Spindle running
Total running hours of spindle motor (Resettable)
H15
LOAD COUNT
Loading counter
Total loading counts of disc (Resettable)
H16
LASER1
Laser parameter 1 Total output hours of laser on optical block assembly (OP1) (Resettable)
H17
SEEK HOURS1
Seek running 1
Total running hours of seek on optical block assembly (OP1) (Resettable)
How to exit form the hours meter
Press the
[MENU]
button or
EXIT (F6)
button.
5-1-3. Periodic Check/Replacement Parts List
This table does not describe the guarantee period of each part.
The replacement period of each part is changed according to the environment and condition.
No.
Part to Be Replaced
Hours Meter (Menu item)
Check/Replacement Period
Parts Number and Name
Section
1
Optical block assembly
Laser parameter
Replace every 6000.
!
8-820-389-02
6-8
(LASER PARAMETER)
KES-330A/J1RP
2
Seek motor
Seek running hours
Replace every 12000 H.
A-1374-689-A
6-9
(SEEK RUNNING)
Seek motor assembly
3
Cleaner assembly
Laser parameter
Check every 6000.
A-1541-288-A
6-4
(LASER PARAMETER)
Replace when bristles of brush
Cleaner (P200) assembly
become sparse or damaged
remarkably.
4
EM-6 board
Laser parameter
Replace around the same time
A-1201-481-A
6-12-14
(LASER PARAMETER)
as optical block assembly.
EM-5S board
5
Lithium battery
Current-carrying hours
About 10 years
!
1-767-156-11
1-9
(for NVRAM)
(OPERATION)
M4T28-BR12SH1
6
Loader assembly
Disc loading count
*
Replace every 110,000 times.
A-1541-722-A
6-3
(LOADING)
Loader (P200) assembly (RP)
*
: This count differs from the actual disc insertion times because the loader up/down count is made by the normal loading operation.
5-1-2. Digital Hours Meter
The elapsed operation time or count of the unit is displayed.
Use this digital hours meter as a guide to periodic check/replacement.
Displaying Digital Hours Meter
1. Display the setup menu with the
[MENU]
button.
2. Select “HOURS METER” with rotate the
[PUSH|SET]
knob or the
[(]
/
[)]
button, and press the
[PUSH|SET]
knob or
SELECT (F2)
button.
Содержание XDCAM PDW-HD1500
Страница 29: ...1 21 PDW HD1500 V1 E HD video outputs 75 Color Bars Black SD video outputs 75 Color Bars Black ...
Страница 36: ......
Страница 46: ......
Страница 94: ......
Страница 158: ......
Страница 160: ...Printed in Japan Sony Corporation 2009 6 16 2008 PDW HD1500 SY PDW HD1500 CN E 9 968 423 04 ...