2-4
PDW-HD1500/V1 (E)
(Continued)
Main
Sub
Time data
Maintenance
Drive
Description
code
code
display
logger
logger
06
049
←
O
O
OP (OP0) SA actuator cannot move to the target position.
0C9
←
O
O
OP (OP1) SA actuator cannot move to the target position.
E41
←
O
O
OP (OP0) SA actuator home position cannot be detected during startup
adjustment.
EC1
←
O
O
OP (OP1) SA actuator home position cannot be detected during startup
adjustment.
F41
←
O
O
OP (OP0) SA actuator home position cannot be detected during power-on
initialization.
FC1
←
O
O
OP (OP1) SA actuator home position cannot be detected during power-on
initialization.
08
091
←
O
O
Spindle motor does not rotate after the predetermined time has passed
(or no FG signal is detected).
095
←
O
O
Spindle motor cannot be stopped (or abnormal FG signal is detected).
292
←
O
O
Spindle motor rotation is detected during vertical move of loading.
*
992
←
O
O
Spindle motor rotation is detected during vertical move of unloading.
*
*
: The vertical move of loading/unloading is also carried out by STBY ON/OFF.
n
Any number of the following is applicable for “X” in the sub codes above, showing an operation status
where the error is detected.
Example) 527: Laser current of optical block assembly is abnormal (zero or excessive) “reading”.
0:
Operation cannot be identified or no need to be identified.
1:
During loading
2:
During vertical move of loading
3:
Disc is not rotating
4:
Seeking
5:
Reading
6:
Writing
7:
Standby state
8:
Ejecting
9:
Unchucking
A:
During disc removal
B:
During lens cleaning or device checking
C, D: (Not used)
E:
During startup adjustment of optical block assembly
F:
During power-on initialization of optical block assembly
Содержание XDCAM PDW-HD1500
Страница 29: ...1 21 PDW HD1500 V1 E HD video outputs 75 Color Bars Black SD video outputs 75 Color Bars Black ...
Страница 36: ......
Страница 46: ......
Страница 94: ......
Страница 158: ......