1-12
HDW-750/750CE V1
1-5. Opening and Closing the Inside
Panel Assembly
Opening
m
.
Be sure to set the POWER switch to OFF, unplug the
power cord or remove the battery before starting any of
the following procedure to protect inside of the unit from
damage.
.
Insert a piece of paper between the hinge and the
connector box only when the connector box is installed.
1.
Loosen the four screws (with drop-safe) and open the
inside panel assembly in the direction of the arrow.
m
.
The flexible card wire that is connected to the FP-
121 board, will be significantly shortened its life if it
is folded. Be very careful not to fold the flexible
card wire.
.
Stand the unit in the posture that the POWER switch
side faces upward when the inside panel assembly is
opened.
Closing
1.
Check that the hinges in the right and left are engaged
securely with the hooks of the chassis.
2.
Insert the inside panel assembly and tighten the four
screws (with drop-safe).
n
Standard tightening torque :
Screw (with drop-safe, B3
x
12)
80
x
10
_
2
N
.
m (8 kgf
.
cm)
n
Be careful not to pinch the harness between the inside
panel assembly and the chassis.
Flexible
card wires
Inside panel
assembly
FP-121 board
Inside panel
assembly
Hook
Insert a piece of paper
into the protection block.
(Only when the connector
box is installed.)
Hinge
POWER switch
Hinge
Hook
Screw
(with drop-safe)
Screw (with drop-safe)
Screws
(with drop-safe)
1-5. Opening and Closing the Inside Panel Assembly