4-19
HDW-750/750CE V1
TEST OUT Display (Setting on TEST OUT and return video)
Item
Setting
Function
TEST OUT MARKER
OFF/ON
Turns ON/OFF the function to output the VF marker to the
TEST OUT terminal.
TEST OUT VFDISP
OFF/ON
Turns ON/OFF the function to output the characters that
appear on VF, to the TEST OUT terminal when the VF’s
DISPLAY switch is set to ON.
TEST OUT MENU
OFF/ON
Turns ON/OFF the function to output the menus that appear
on VF, to the TEST OUT terminal when the MENU ON/OFF
switch is set to ON.
TEST OUT ZEBRA
OFF/ON
Turns ON/OFF the function to output the zebra pattern to the
TEST OUT terminal.
OUTPUT SELECT
Y/R/G/B/RGB
*
1
Selects the video signal that is output from the TEST OUT and
the VBS/SDI OUT terminal.
(The Y-signal becomes the VBS signal when the REAR BNC
OUT SEL of the OUTPUT SEL display (of the OPERATION
menu) selects the VBS position and when the TEST OUT
SELECT chooses the SD position.) The output signal returns
to the Y-signal without fail at power-on.
*
1 : RGB can be selected only when the Camcorder is used in the service mode.
n
When an NTSC system VF or monitor is connected, the MARKER and ZEBRA displays are not output
when “DOWN CON MODE” of the OUTPUT SEL display is CROP.
? 15
O
TEST OUT
TEST OUT MARKER : OFF
TEST OUT VFDISP : OFF
TEST OUT MENU : OFF
TEST OUT ZEBRA : OFF
OUTPUT SELECT : Y
4-4. OPERATION Menu