4-67
HDW-750/750CE V1
MANUAL RPN Display (Adjusting the DC value of the RP-123/RP-127 board)
Item
Setting
Function
OUTPUT SELECT
Y/R/G/B/RGB
*
1
Selects the video signal that is output from the TEST OUT
and the VBS/SDI OUT terminal.
(The Y-signal becomes the VBS signal when the REAR
BNC OUT SEL of the OUTPUT SEL display (of the
OPERATION menu) selects the VBS position and when
the TEST OUT SELECT chooses the SD position.)
The output signal returns to the Y-signal without fail at
power-on.
RPN CURSOR
OFF/ON
Turns ON/OFF the cursor for RPN.
TEST OUT MENU
OFF/ON
Turns ON/OFF the function to mix the menu display in the
output signal of the TEST OUT terminal.
CURSOR H POS.
_
480 to 479
Sets the position of the RPN cursor. (Horizontal direction)
CURSOR V POS.
_
270 to 269
Sets the position of the RPN cursor. (Vertical direction)
RECORD RPN
Press the rotary encoder
Registers the RPN data of the present cursor position.
to execute this menu item.
FIELD/FRAME
FIELD/FRAME
Sets the CCD read-out system.
FIELD : Field reading-out (normal readout)
FRAME : Frame reading-out
(This position is used to obtain the higher
vertical resolution power.)
Reference : When the super EVS (high vertical resolution)
mode is set to ON, FIELD is selected forcibly.
*
1 : RGB can be selected only when the Camcorder is used in the service mode.
4-9. SERVICE Menu
? 07
O
MANUAL RPN
OUTPUT SELECT : Y
RPN CURSOR : OFF
TEST OUT MENU : OFF
CURSOR H POS. : 0
CURSOR V POS. : 0
RECORD RPN : EXEC
FIELD/FRAME : FIELD