9-9
HDW-750/750CE V1
2.
Complete the adjustment as shown below by using the
setup menu.
Measurement point : TP4/EX-776 board
(DR extension assembly)
MENU :
SERVICE
PAGE :
07
*
RP DC OFFSET
ITEM :
G DC OFFSET 0
ITEM :
G DC OFFSET 180
Specifications :
DC voltage of the portion A must
be 0
±
100 mV and carrier leak at
the portion B must be minimum
at the same time.
3.
Complete the adjustment as shown below by using the
setup menu.
Measurement point : TP6/EX-776 board
(DR extension assembly)
MENU :
SERVICE
PAGE :
07
*
RP DC OFFSET
ITEM :
B DC OFFSET 0
ITEM :
B DC OFFSET 180
Specifications :
DC voltage of the portion A must
be 0
±
100 mV and carrier leak at
the portion B must be minimum
at the same time.
9-7. VSUB Adjustment
n
In the HDW-730, do not perform this adjustment.
Preparation
.
OUTPUT/DCC switch (inside panel)
→
CAM/ON
.
Shoot an all white chart with a high illumination to fill
the entire screen of the under-scanned picture frame.
.
Lens iris
→
Open
Adjustment Procedure
1. Complete the adjustment as shown below by using the
setup menu.
Measurement point : TP2/EX-776 board
(DR extension assembly)
MENU :
SERVICE
PAGE :
04
*
CCD ADJUST
ITEM :
R VSUB
Specifications :
3.20
±
0.10 V
2.
Complete the adjustment as shown below by using the
setup menu.
Measurement point : TP4/EX-776 board
(DR extension assembly)
MENU :
SERVICE
PAGE :
04
*
CCD ADJUST
ITEM :
G VSUB
Specifications :
3.20
±
0.1 V
3.
Complete the adjustment as shown below by using the
setup menu.
Measurement point : TP6/EX-776 board
(DR extension assembly)
MENU :
SERVICE
PAGE :
04
*
CCD ADJUST
ITEM :
B VSUB
Specifications :
2.00
±
0.05 V
9-6. Black Offset Adjustment
9-7. VSUB Adjustment