9-21
HDW-750/750CE V1
9-19. Detail Signal Frequency
Adjustment
Note
Perform this adjustment as needed by the customer.
Preparation
.
Complete the setting as shown below by using the setup
menu.
MENU : PAINT
PAGE : 07
*
DETAIL1
ITEM :
DETAIL
→
ON
.
OUTPUT/DCC switch (inside panel)
→
CAM/ON
.
Shoot the gray scale chart to fill the entire screen of the
under-scanned picture frame.
Equipment :
HD digital waveform monitor
Measurement point : HD SDI connector (rear panel)
Adjustment point :
1
lens iris
Specifications :
A = 700
±
14 mV.
.
Select a horizontal scanning line in the bottom of the
white area in the center of the waveform monitor using
the LINE SELECT function.
Adjustment Procedure
Equipment :
HD digital waveform monitor
Measurement point : HD SDI connector (rear panel)
1.
Complete the adjustment as shown below by using the
setup menu.
MENU :
PAINT
PAGE :
07
*
DETAIL1
ITEM :
DETAIL FREQ.
Specifications : Adjust the edge width of the B portion
for the customer’s preference.
Note
Upon completion of this adjustment, be sure to perform the
following two adjustments : “9-20. H/V Ratio Adjustment”
and “9-21. Detail Signal Level Adjustment”.
A
B
9-19. Detail Signal Frequency Adjustment