7-61
HDW-750/750CE V1
Installation
2. Installing the holder assembly sensor
(REC)
Insert the bosses and claws of the new holder
assembly sensor (REC) into four holes of the
MDC-13 board and install the new holder assem-
bly sensor (REC).
3. Operation check
Check that the detection pin moves up and down
smoothly, and returns to the original position.
MDC-13 board
Holder assembly sensor (REC)
Claw
Claw
Boss
Boss
Holes
Holes
7-14. Holder Assembly Sensor (REC) Replacement