8-12
HDW-750/750CE V1
8-1-6. T Tension Regulator Operating Position Adjustment
Note
When the T-tension regulator band assembly and the T reel table assembly is
replaced, be sure to perform the T tension regulator operating position adjustment.
Preparations
1.
Turn off the main power.
2.
Remove the front lid and the outside panel assembly. (Refer to Section 1-4.)
3.
Remove the cassette compartment. (Refer to Section 1-9.)
4.
Confirm that the unit is in the unthreading-end state.
Tools
.
Torque screwdriver bit (for M2) :
J-6325-380-A
.
Torque screwdriver (for 3 kg) :
J-6325-400-A
Check Procedure
1. Setting up the mode
Rotate the manual eject gear (A) counter-clock-
wise until the unit reaches the threading-end state.
(Refer to Section 7-1-3.)
2. T tension regulator operating position
check
Specifications :
The round hole of the pinch arm assembly can be
viewed through the square hole of the T tension
regulator assembly.
m
.
Check that the round hole is not damaged when
viewed from the top.
.
If the specification is not satisfied, perform
adjustment as described in step 3.
T-tension regulator
assembly
T-Tension regulator
band assembly
Pinch arm
assembly
Round hole of pinch arm
assembly
Eject link assembly (B)
Square hole of T-tension
regulator assembly
T reel table
assembly
Adjustment screw
Hole for adjustment
8-1. Mechanical Adjustment