9-13. Flare Adjustment
Preparation
.
Lens iris
→
MAN
.
OUTPUT/DCC switch (inside panel)
→
CAM/ON
.
WHITE BAL switch (inside panel)
→
A
.
Shoot a gray-scale chart to fill the entire screen of the
under-scanned picture frame and execute AWB.
Equipment :
HD digital waveform monitor
Measurement point : HD SDI connector (outside panel)
Adjustment point :
Open the lens iris by 1 F-stop
from the reference value
(A = 700
±
14 mV).
Adjustment Procedure
Equipment :
HD digital waveform monitor
Measurement point : HD SDI connector (outside panel)
1.
Complete the setting as shown below by using the
setup menu.
MENU : PAINT
PAGE : 03
*
BLACK
ITEM :
G FLARE
→
0
2.
Select a horizontal scanning line in the portion B on
the waveform monitor using the LINE SELECT
function.
3.
Complete the adjustment as shown below by using the
setup menu.
MENU :
PAINT
PAGE :
03
*
BLACK
ITEM :
R FLARE
Specifications : Minimize the color difference level at
the portion C.
4.
Complete the adjustment as shown below by using the
setup menu.
MENU :
PAINT
PAGE :
03
*
BLACK
ITEM :
B FLARE
Specifications : Minimize the color difference level at
the portion C.
5.
Repeat steps 3 and 4 several times.
A
B
C
9-13. Flare Adjustment