7-11
HDW-750/750CE V1
2. Removing connector from brush
assembly
Remove the connector from the brush assembly.
3. Removing the full top sensor
assembly
Remove the precision screw. While removing the
connector on the MDC-13 board, remove the full
top sensor assembly.
n
When removing the full top sensor assembly, be
very careful not to touch the drum.
Precision screw
P1.4
x
3.5
MDC-13 board connector
Brush assembly (RP)
Full top sensor
assembly
4. Removing the drum assembly
n
The drum assembly is fixed by the two screws.
The drum assembly is connected with the MDR-
14 board on the rear of the mechanical deck with
connector. Due to these connections, do not put
excessive force to the dum assembly even after
the two screws are removed.
n
When removing the drum assembly, be careful
not to touch the CTL head, CUE head and nearby
tape guides.
Remove the two screws. Hold the upper part of
the brush support. While loosening the connector
on the MDR-14 board, remove the drum assem-
bly.
7-2. Upper Drum Assembly Replacement
Connectors on
the MDR-14 board
Drum assembly
PSW2
x
5
PSW2
x
5