RB6741-Z Touchscreen Security System Installation Manual
14. If you enabled Send Test Alarm Messages, contact the central-monitoring station test
number to ensure that they received all the generated alarms. If all the alarms were
received successfully, tell them that you are no longer testing alarms.
15. Touch
Next
to return to the Settings menu.
Table 4-1. Sensor Testing Operations
Sensor
Testing Process
Door/Window
Open and close the door or window.
Motion Detector
Avoid the motion detector’s view for three minutes after arming the system, then walk in front of it.
Smoke Detector
Press and hold the sensor’s
Test
button until the siren sounds (approx. 10 seconds).
Glass Break Detector
Use a glass break simulator.
Key Fob
Arm and disarm system with the key fob.
Key Pad
Arm and disarm system with the key pad.
Configuring Entry/Exit Delay Periods
The Entry Delay period is the amount of time from an Entry/Exit sensor being faulted until an
alarm sounds. The customer has until the end of the Entry Delay period to enter a valid key
pad code. There is no Entry Delay period for perimeter-type sensors, such as window
sensors or non-entry door sensors. There is an audible beeping during the Entry Delay
period that is not configurable and cannot be muted.
The Exit Delay period is the amount of time that starts when the security system is armed.
The customer has this period of time to exit through an Entry/Exit sensor doorway. If the
customer does not exit during this period, the system cannot be armed in Arm Away state.
The system will arm in Arm Stay state. There is an audible beeping during the Exit Delay
(once per second) that speeds up during the last 10 seconds of the Exit Delay (twice per
second).
The Entry/Exit Delay periods are configurable by an installer.