General Concepts of
the Security System
172
RB6741-Z Touchscreen Security System Installation Manual
The Alarm Transmission Delay period (also called the Abort Window) is the length of time
after an alarm sounds for the customer to enter a valid keypad code. This period starts when
the customer fails to enter his keypad code during the Entry Delay period. The central-
monitoring station is not contacted until after the Alarm Transmission Delay period. This
helps prevent false alarms. During an alarm, the system can be disarmed by entering a valid
keypad code in the Touchscreen or a key pad peripheral. As soon as the customer enters a
single digit in the keypad screen or on the key pad peripheral, the Touchscreen alarm is
temporarily silenced. If the user enters an invalid keypad code, the alarm starts again. If the
alarm system is disarmed with a keypad code within the Alarm Transmission Delay period,
no alarm transmission shall occur.
The persons named on the Contact list can opt to receive SMS and/or email messages
notifying them when an alarm was aborted and that central monitoring was not notified. By
default, Verify contacts are notified by SMS through email when an alarm is disarmed during
the Alarm Transmission Delay period.
After the Alarm Transmission Delay period is completed, the customer still has 5 minutes
(the Cancel Window) to disarm the system. If the customer does this during the Cancel
Window and central monitoring has not contacted him or her, central monitoring is
automatically notified that the customer has cancelled the alarm.
The Duress Code
The Duress keypad code is used if an intruder forces the customer to disarm her system or
access her security settings. Rather than entering her keypad code, she enters the Duress
keypad code. When she does this, she is granted full access to her Touchscreen, but a
silent alarm is immediately sent to the central monitoring station and police are dispatched.
The Duress Code is enabled and configured from the
Manage Keypad Code
s screen
accessible from the Settings Widget.