Technician
Operations
150
RB6741-Z Touchscreen Security System Installation Manual
The Home Devices screen appears.
3.
Touch
Panel Interfaces > Add Panel
Interface Boards
. The Locating Panel
Interface Boards screen appears.
Observe the following:
The Takeover Board can be located
only within the first 90 seconds of
powering up. The Alarm Panel
Alphanumeric Keypad should display
Scanning for Network. If not, press any
button on the keypad to restart the
process or cycle power to the Takeover
Board.
A zone managed by the alarm panel
might contain multiple sensors. When
these zones are paired with the
Touchscreen, they are located as a
single sensor. A wired zone that
contains five smoke detectors, for
example, is managed by the
Touchscreen as if the detectors are a
single smoke detector.