Instruction Manual ScrubberGuard
Servicing
72
14830E/2
The current flow rate values can be seen in the
Local\Scrubber
menu:
Figure 30: Scrubber menu / Flow rate
A1 Flow Tu:
Flow rate through the
AquaScat SG in l/min. Standard nominal
value = 6 l/min. If deviations of more than
+/- 1 l/min from the nominal value occur,
the FLOW RATE warning is output.
A2 Flow Oi:
Flow rate through the Oil-
Guard SG in l/min. Standard nominal value
= 6 l/min. If deviations of more than +/- 1
l/min from the nominal value occur, the
FLOW RATE warning is output.
C8 Flow In:
Flow rate into the Scrubber-
Guard in l/min. Minimum = 4 l/min. If the
minimum value is undershot, a WATER
SHORTAGE fault is output.
Green status display: Flow rate in permis-
sible range.
Red status display: Flow rate in impermis-
sible range.
If the flow rate drops to around zero, the
system is stopped after around six minutes
and the SCRUBBER SYS. fault message is
output.
Scrubber:
A system code is output next to
the
Scrubber
menu item. This helps with
troubleshooting. More detailed information
can be found in the Reference Handbook.
V: Firmware version
L: Fill level on water tank
H: Hydraulic status
S: Control status
U: Noncritical faults
C: Critical faults