Instruction Manual ScrubberGuard
Servicing
88
14830E/2
WORKSTEP
ADDITIONAL INFO / IMAGES
4.
Remove the capacitors from the terminal box.
The capacitor can discharge
when touched.
Ensure that the capacitor is dis-
charged.
5.
Unplug the connectors from the old capaci-
tors, or disconnect the cables if using crimp
connections.
Note down or label the cable
positions.
6.
Connect the new capacitors electrically using
the supplied WAGO terminals.
7.
Stow away the capacitors in the terminal box.
In doing so, ensure that the cables cannot
become trapped or chafed.
8.
Fasten the cover back onto the terminal box
using the four screws. Ensure that the seal is
seated correctly.
9.
Ensure that the switch (when available) on the
electrical terminal box is set to
ON
.
The switch is located to
the rear on the electrical terminal
box of the pump.
10. Remove the padlock on the main switch and
then switch the system back on.
11. Reattach the casing to the system.
12. Put the system back into operation according
to Section 6.