Electrical installation
Instruction Manual ScrubberGuard
14830E/2
35
5.3
Connecting the service voltage in the cabinet
DANGER!
Life-threatening voltage inside the instrument.
Before opening the cabinet, ensure that the system is de-energized.
Figure
10
: Connecting the service voltage
▪
The cable gland for the mains connection is designed for cables with an outer diame-
ter of 5 to 10 mm.
▪
Shielded connection cables must be used on systems with frequency converters.
To connect the service voltage, the cabinet must be opened as described in Section 5.2. The
terminals are designed for cross-sections up to 4 mm
2
. Establish the electric connections ac-
cording to the following sequence:
TERMINALS
MEANING
REMARKS
1.
1
Green / Yellow
2.
2
N
Blue
3.
3
P
Orange