Chapter 21
| Multicast Filtering Commands
IGMP Snooping
– 507 –
Command Usage
◆
When a multicast host leaves a group, it sends an IGMP leave message.
When the leave message is received by the switch, it checks to see if this
host is the last to leave the group by sending out an IGMP group-specific
or group-and-source-specific query message, and starts a timer. If no
reports are received before the timer expires, the group record is deleted,
and a report is sent to the upstream multicast router.
◆
A reduced value will result in reduced time to detect the loss of the last
member of a group or source, but may generate more bursty traffic.
◆
This command will take effect only if IGMP snooping proxy reporting is
enabled (
).
Example
Console(config)#ip igmp snooping vlan 1 last-memb-query-intvl 700
Console(config)#
ip igmp snooping vlan
mrd
This command enables sending of multicast router solicitation messages. Use
the
no
form to disable these messages.
Syntax
[
no
]
ip igmp snooping vlan
vlan-id
mrd
vlan-id
- VLAN ID (Range: 1-4094)
Default Setting
Disabled
Command Mode
Global Configuration
Command Usage
◆
Multicast Router Discovery (MRD) uses multicast router advertisement,
multicast router solicitation, and multicast router termination messages to
discover multicast routers. Devices send solicitation messages in order to
solicit advertisement messages from multicast routers. These messages
are used to discover multicast routers on a directly attached link.
Solicitation messages are also sent whenever a multicast forwarding
interface is initialized or re-initialized. Upon receiving a solicitation on an
interface with IP multicast forwarding and MRD enabled, a router will
respond with an advertisement.
◆
Advertisements are sent by routers to advertise that IP multicast
forwarding is enabled. These messages are sent unsolicited periodically
on all router interfaces on which multicast forwarding is enabled. They are
sent upon the expiration of a periodic timer, as a part of a router's start up
Содержание SC30010
Страница 1: ...C 300 Series Gigabit Managed Switch CLI Reference Guide SOFTWARE RELEASE V1 1 10 171 www signamax com ...
Страница 2: ...CLI Reference Guide SC30010 C 300 48 Port Gigabit Managed Switch E122017 KS R01 ...
Страница 482: ...Chapter 19 Class of Service Commands Priority Commands Layer 3 and 4 482 ...
Страница 670: ......
Страница 671: ...E122017 KS R01 ...