Chapter 11
| Interface Commands
– 367 –
Command Mode
Privileged Exec
Command Usage
◆
The switch can display diagnostic information for SFP modules which
support the SFF-8472 Specification for Diagnostic Monitoring Interface for
Optical Transceivers. This information allows administrators to remotely
diagnose problems with optical devices. This feature, referred to as Digital
Diagnostic Monitoring (DDM) in the command display, provides
information on transceiver parameters including temperature, supply
voltage, laser bias current, laser power, received optical power, and
related alarm thresholds.
◆
The DDM thresholds displayed by this command only apply to ports which
have a DDM-compliant transceiver inserted.
Example
Console#show interfaces transceiver-threshold ethernet 1/25
Information of Eth 1/25
DDM Thresholds
Transceiver-monitor : Disabled
Transceiver-threshold-auto : Enabled
Low Alarm Low Warning High Warning High Alarm
----------- ------------ ------------ ------------ ------------
Temperature(Celsius) -123.00 0.00 70.00 75.00
Voltage(Volts) 3.10 3.15 3.45 3.50
Current(mA) 6.00 7.00 90.00 100.00
TxPower(dBm) -12.00 -11.50 -9.50 -9.00
RxPower(dBm) -21.50 -21.00 -3.50 -3.00
Console#
Cable Diagnostics
test cable-diagnostics
This command performs cable diagnostics on the specified port to diagnose
any cable faults (short, open, etc.) and report the cable length.
Syntax
test cable-diagnostics dsp interface
interface
interface
ethernet
unit
/
port
unit
- Unit identifier. (Range: Always 1)
port
- Port number. (Range: 1-22/48)
Command Mode
Privileged Exec
Содержание SC30010
Страница 1: ...C 300 Series Gigabit Managed Switch CLI Reference Guide SOFTWARE RELEASE V1 1 10 171 www signamax com ...
Страница 2: ...CLI Reference Guide SC30010 C 300 48 Port Gigabit Managed Switch E122017 KS R01 ...
Страница 482: ...Chapter 19 Class of Service Commands Priority Commands Layer 3 and 4 482 ...
Страница 670: ......
Страница 671: ...E122017 KS R01 ...