Operation
6.3 Basic information about the drive system
Converter cabinet units
268
Operating Instructions, 07/2016, A5E03347396A
Example of data set assignment
Table 6- 2
Example, data set assignment
DDS
Motor (p0186)
Encoder 1 (p0187) Encoder 2 (p0188) Encoder 3 (p0189)
DDS 0
MDS 0
EDS 0
EDS 1
EDS 2
DDS 1
MDS 0
EDS 0
EDS 3
--
DDS 2
MDS 0
EDS 0
EDS 4
EDS 5
DDS 3
MDS 1
EDS 0
--
--
Copying the command data set (CDS)
Set parameter p0809 as follows:
1.
p0809[0] = number of the command data set to be copied (source)
2.
p0809[1] = number of the command data to which the data is to be copied (target)
3.
p0809[2] = 1
Start copying.
Copying is finished when p0809[2] = 0.
Copying the drive data set (DDS)
Set parameter p0819 as follows:
1.
p0819[0] = Number of the drive data set to be copied (source)
2.
p0819[1] = Number of the drive data set to which the data is to be copied (target)
3.
p0819[2] = 1
Start copying.
Copying is finished when p0819[2] = 0.
Copy motor data set (MDS)
Set parameter p0139 as follows:
1.
p0139[0] = Number of the motor data set that is to be copied (source)
2.
p0139[1] = Number of the motor data set which should be copied into (target)
3.
p0139[2] = 1
Start copying.
Copying has been completed, if p0139[2] = 0.
Содержание SINAMICS G150
Страница 1: ......
Страница 2: ......
Страница 8: ...Foreword Converter cabinet units 8 Operating Instructions 07 2016 A5E03347396A ...
Страница 18: ...Table of contents Converter cabinet units 18 Operating Instructions 07 2016 A5E03347396A ...
Страница 38: ...Device overview 2 5 Type plate Converter cabinet units 38 Operating Instructions 07 2016 A5E03347396A ...
Страница 679: ......
Страница 680: ......