Commissioning
5.5 First commissioning with the AOP30
Converter cabinet units
246
Operating Instructions, 07/2016, A5E03347396A
Note
Selecting the motor type
The selection of the motor type pre-assigns specific motor parameters and optimizes the
operating characteristics and behavior. Details are described in the List Manual in the p0300
parameter.
Note
Selection of a list motor (p0300
≥
100)
When a motor type ≥
100 is selected, the article number of the associated motor can be
selected via drop-down list.
Note
Commissioning of an induction motor
The steps described below also apply to commissioning an induction motor.
When commissioning a permanent-magnet synchronous motor (p0300 = 2), there are a few
special conditions that apply, which are detailed in a separate chapter (see "Setpoint
channel and closed-loop control/Permanent-magnet synchronous motors").
Winding type selection
Entry of the origin for the line contactor
checkback signal: the default setting should
remain as it is.
Selecting the winding type:
•
Single winding system
•
Several separate winding systems or
motors (default setting)
Navigate within the selection fields with <F2>
and <F3>.
Activate your selection with <F5>.
Once you have entered the final value,
choose "Continue" to exit the screen.
Содержание SINAMICS G150
Страница 1: ......
Страница 2: ......
Страница 8: ...Foreword Converter cabinet units 8 Operating Instructions 07 2016 A5E03347396A ...
Страница 18: ...Table of contents Converter cabinet units 18 Operating Instructions 07 2016 A5E03347396A ...
Страница 38: ...Device overview 2 5 Type plate Converter cabinet units 38 Operating Instructions 07 2016 A5E03347396A ...
Страница 679: ......
Страница 680: ......