Commissioning
5.3 Procedure for commissioning with STARTER
Converter cabinet units
Operating Instructions, 07/2016, A5E03347396A
239
11.The SINAMICS drive is displayed as drive object in the project navigator.
12.You can now configure the drive unit (see Chapter "Configuring the drive unit").
Note
Storage location of the IP address
The IP address and device name are stored on the memory card of the Control Unit (non-
volatile).
Parameter
Parameters can also be used to modify and/or display the properties of the Ethernet
interface.
•
p8900
IE name of station
•
p8901
IE IP address of station
•
p8902
IE default gateway of station
•
p8903
IE subnet mask of station
•
p8904
IE DHCP mode
•
p8905
IE interface configuration
•
r8910
IE name of station active
•
r8911
IE IP address of station active
•
r8912
IE default gateway of station active
•
r8913
IE subnet mask of station active
•
r8914
IE DHCP mode of station active
•
r8915
IE MAC address of station