Commissioning
5.3 Procedure for commissioning with STARTER
Converter cabinet units
222
Operating Instructions, 07/2016, A5E03347396A
⇒
To select a different predefined encoder configuration, check the Select standard encoder
from list radio button and select one of the encoders from the list.
⇒
To enter special encoder configurations, click the Enter data radio button and then the
Encoder data button. The following input screen is displayed for you to enter the required
data.
Figure 5-25 Entering encoder data – User-defined encoder data
⇒
Select the measuring system.
In conjunction with SINAMICS G150, the following encoders can be selected:
●
HTL
●
TTL
⇒
Enter the required encoder data.
⇒
Under the Details tab, special encoder properties can be set, for example, gear ratio, fine
resolution, inversion, measuring gear position tracking.
⇒
Click OK.