1FT5
08.95
1FT5/1-4
Siemens AG 1997 All Rights reserved 6SN1197–0AA20
SIMODRIVE 611 (PJ)
Rated
speed
[
RPM
]
Cable type
6FX
V
002–
4)
Cross–
section
1)
[
mm
2
]
Connec-
tor size
P
rated
[
kW
]
Rated
drive
converter
current
[
A]
Motor
current
I
0
[
A
]
Motor type
1FT5–
M
rated
[
Nm
]
M
0
[
Nm
]
4000
2.6
5.5
8
2.2
3.8
5.5
062–
V
AG71
064–
V
AG71
066–
V
AG71
3.2
6.7
9.6
4
7.5
12.5
0.9
1.6
2.3
1
1
1
4x1.5
4x1.5
4x1.5
5
V
A01–1
VV
0
5
V
A01–1
VV
0
5
V
A01–1
VV
0
12
18
22
20.5
26
33
40
7.5
11
13
17
21
10
32
072–0AG71
074–0AG71
076–0AG71
074–0SG71
076–0SG71
102–0AG71
102–0SG71
14.4
21.5
26.0
24.5
31.0
38.5
46.5
25
25
25
3)
25
40
40
40
3.1
4.6
5.4
7.1
8.8
4.2
13.4
1
2
2
2
2
2
3
4x2.5
4x4
4x6
4x4
4x6
4x10
4x16
5
V
A11–1
VV
0
5
V
A12–1
VV
0
5
V
A22–1
VV
0
5
V
A12–1
VV
0
5
V
A22–1
VV
0
5
V
A32–1
VV
0
5
V
A23–1
VV
0
6000
0.9
1.3
1.0
0.76
1.0
0.9
034–
V
AK71
036–
V
AK71
042–
V
AK71
1.6
2.3
1.7
4
4
4
0.5
0.6
0.56
1
1
1
4x1.5
4x1.5
4x1.5
5
V
A01–1
VV
0
5
V
A01–1
VV
0
5
V
A01–1
VV
0
2.0
1.65
044–0AK71
3.4
4
1.0
1
4x1.5
5
V
A01–1
VV
0
3.7
2.7
046–
V
AK71
6.3
7.5
1.7
1
4x1.5
5
V
A01–1
VV
0
2.6
5.5
8.
12
18
22
20.5
26
2.1
3.0
4.2
5.0
7.0
4.0
12
15
062–0AK71
064–0AK71
066–0AK71
072–0AK71
074–0AK71
076–0AK71
074–0SK71
076–0SK71
4.6
9.8
14.5
21.0
32.0
39.0
36.0
46.0
7.5
12.5
25
25
40
40
40
40
1)
1.3
1.9
2.6
3.1
4.4
2.5
7.5
9.4
1
1
1
2
2
2
2
3
4x1.5
4x1.5
4x2.5
4x4
4x6
4x10
4x10
4x16
5
V
A01–1
VV
0
5
V
A01–1
VV
0
5
V
A11–1
VV
0
5
V
A12–1
VV
0
5
V
A22–1
VV
0
5
V
A32–1
VV
0
5
V
A32–1
VV
0
5
V
A23–1
VV
0
1
Core type
0
Not a core type
without brake cable: without overall screen A
with overall screen
C
with brake cable:
without overall screen B
with overall screen
D
Lengths
2)
5 m
AF
(examples)
10 m
BA
15 m
BF
18 m
BJ
25 m
CF
Cables are not included with the motors,
they must be separately ordered.
Actual value cable, refer to Chapter Encoders (GE).
1) Designed for I
0rms
= I
0[100 k]
2/3 ; ambient temperature 40
°
C; PVC–insulated cable; brake connection 2 x 1 mm
2
.
2) Cables can be supplied in incremental lengths of 1 meter; length code, refer to Chapter AL S/4.3.
3) With the specified power module, the motor cannot be fully utilized to 100 K winding temperature.
4) 2=Performance cable; 4=Standard cable; Technical data, refer to Catalog NC Z
1FT5 AC servomotors
01.98
1.1 Characteristics and technical data
Содержание SIMODRIVE 611A
Страница 2: ......
Страница 6: ......
Страница 7: ...SECTION 0 PRELIMINARY INFORMATION 0 7 ...
Страница 8: ......
Страница 17: ...Section 1 611A Analog Feed Drives 1 17 ...
Страница 18: ...1 18 ...
Страница 24: ...1 24 ...
Страница 39: ...1 39 ...
Страница 70: ...1 70 ...
Страница 119: ...1 119 ...
Страница 120: ......
Страница 123: ......
Страница 131: ......
Страница 158: ...1 158 ...
Страница 159: ...1 159 MOUNTING DIMENSIONS ...
Страница 160: ...1 160 ...
Страница 186: ......
Страница 187: ...GENERAL INFORMATION REGARDING AC SERVO MOTORS AL S ...
Страница 188: ......
Страница 225: ...1FT5 AC SERVO MOTOR DESCRIPTIONS 1FT5 ...
Страница 226: ......
Страница 321: ...FEEDBACK DEVICES FOR 1FT5 GE ...
Страница 322: ......