3
02.98
1-22
Siemens AG 1998 All Rights reserved 6SN1197–0AA00 02.98 Edition
SIMODRIVE 611 (PJ)
This function is only available in conjunction with I/R modules
Order No.: 6SN114
V
–1
VV
0
V
–0
VV
1
OFF: Standard setting, controlled infeed active
ON: Uncontrolled operation in the infeed direction V
DC link
=V
supply
1.35
OFF: Square–wave current operation (the line supply is loaded with a
square–wave current)
ON: This function is only available in conjunction with I/R modules
Order No.: 6SN114
V
–1
VV
0
V
–0
VV
1
Sinusoidal current operation (the line supply is loaded with sinusoidal
current)
Sinusoidal current is only permissible if the following
components are available:
I/R
16 kW
I/R
36 kW
I/R
55 kW
I/R
80 kW
I/R
120 kW
6SN114
V
–
1B
V
01–0BA1
6SN114
V
–
1B
V
02–0CA1
6SN114
V
–
1B
V
0
V
–0DA1
6SN114
V
–
1BB00–0EA1
6SN114
V
–
1BB01–0FA1
HF reactor
16 kW
HF reactor
36 kW
HF reactor
55 kW
HF reactor
80kW
HF reactor
120kW
6SN1111–
0AA00–0BA
V
6SN1111–
0AA00–0CA
V
6SN1111–
0AA00–0DA
V
6SN1111–
0AA00–1EA
V
6SN1111–
0AA00–1FA
V
Line filter for
sinusoidal
current
1)
16 kW
Line filter for
sinusoidal
current
1)
36 kW
Line filter for
sinusoidal
filter
1)
55 kW
Line filter for
sinusoidal
current
1)
80 kW
Line filter for
sinusoidal
current
1)
120 kW
6SN1111–
0AA01–2BA
V
6SN1111–
0AA01–2CA
V
6SN1111–
0AA01–2DA
V
6SN1111–
0AA01–2EA
V
6SN1111–
0AA01–2FA
V
!
Important
For all of the combinations which are not listed here, only
square–wave current operation setting is permissible.
Table 3-1 Power factor
I/R
Sinusoidal current operation
cos
ϕ
0.98
cos
λ
= 0.97
I/R
Square–wave current opera-
tion
cos
ϕ
0.98
cos
λ = 0.89
UE
cos
ϕ
0.87
cos
λ = 0.67
cos
ϕ
: The power factor only includes the basic fundamental
cos
λ
: Power factor includes the basic fundamental and harmonic components
1)
In the line filters for sinusoidal operation, contrary to the filter modules 6SN1111–0AA01–0
V
A
V
for square–wave
current, commutating reactors are not included.
The HF commutating reactor must be mounted externally (refer to p. 1-45).
The line filter is required in order to achieve the CE Conformance for the radio interference voltage.
Switch S 1.5 :
Switch S 1.6 :
3.1 Function overview and settings
Содержание SIMODRIVE 611A
Страница 2: ......
Страница 6: ......
Страница 7: ...SECTION 0 PRELIMINARY INFORMATION 0 7 ...
Страница 8: ......
Страница 17: ...Section 1 611A Analog Feed Drives 1 17 ...
Страница 18: ...1 18 ...
Страница 24: ...1 24 ...
Страница 39: ...1 39 ...
Страница 70: ...1 70 ...
Страница 119: ...1 119 ...
Страница 120: ......
Страница 123: ......
Страница 131: ......
Страница 158: ...1 158 ...
Страница 159: ...1 159 MOUNTING DIMENSIONS ...
Страница 160: ...1 160 ...
Страница 186: ......
Страница 187: ...GENERAL INFORMATION REGARDING AC SERVO MOTORS AL S ...
Страница 188: ......
Страница 225: ...1FT5 AC SERVO MOTOR DESCRIPTIONS 1FT5 ...
Страница 226: ......
Страница 321: ...FEEDBACK DEVICES FOR 1FT5 GE ...
Страница 322: ......