VS
07.94
1-101
Siemens AG 1997 All Rights reserved
SIMODRIVE 611A Installation and Start–Up Guide/IAA/–04.97 Edition
Setting the adaptation range (generally not required)
The adaptation range can be set using the following resistors:
R40 User–friendly interface
R543 Standard interface 1st axis (from Order No. 6SN1118–0AD11–0AA1)
R544 Standard interface 2nd axis (from Order No. 6SN1118–0AE11–0AA1)
R
j
= open
R
j
= inserted
Maximum adaptation range (as supplied)
Adapt. reduced acc. to the following diagram
150
130
110
90
70
50
30
10
0
0 50 100 150 200 250 300 350 400
R40 in k
n
x
in mV
Adap
_
ta-
tion
fully
eff_
ec-
tive
Transition range
Adap–
tation
inef-
fect–
ive
Fig. 2-8 Adaptation range
n
x
=
j
n
setp.1
+ n
act.
j
I component limiting of the speed controller
R52 User–friendly interface
R547 Standard interface 1st axis (from Order No. 6SN1118–0AD11–0AA1)
R550 Standard interface 2nd axis (from Order No. 6SN1118–0AE11–0AA1)
R52 = open
R52 =
0 Ω
I component fully effective
(as supplied)
I component ineffective
R52 can be between 100 k
Ω
and 2 M
Ω
to limit the speed controller I compo-
nent, e. g. for slipstick effects.
Feed modules (VS)
04.97
2.6 Setting the adaptation range (generally not required)
Содержание SIMODRIVE 611A
Страница 2: ......
Страница 6: ......
Страница 7: ...SECTION 0 PRELIMINARY INFORMATION 0 7 ...
Страница 8: ......
Страница 17: ...Section 1 611A Analog Feed Drives 1 17 ...
Страница 18: ...1 18 ...
Страница 24: ...1 24 ...
Страница 39: ...1 39 ...
Страница 70: ...1 70 ...
Страница 119: ...1 119 ...
Страница 120: ......
Страница 123: ......
Страница 131: ......
Страница 158: ...1 158 ...
Страница 159: ...1 159 MOUNTING DIMENSIONS ...
Страница 160: ...1 160 ...
Страница 186: ......
Страница 187: ...GENERAL INFORMATION REGARDING AC SERVO MOTORS AL S ...
Страница 188: ......
Страница 225: ...1FT5 AC SERVO MOTOR DESCRIPTIONS 1FT5 ...
Страница 226: ......
Страница 321: ...FEEDBACK DEVICES FOR 1FT5 GE ...
Страница 322: ......