SIMODRIVE 611 (PJ)
Function overview and settings using the parameter board
6SN1114–0AA01–0AA1
Table 7-1
Parameter
Value range
Setting elements
Speed controller
Integral action time
Proportional gain
Adaptation:
Integral action time
Proportional gain
Adaptation range
T
N
= 7...43 ms
Kp = 2...150
T
Nadap
/T
N
= 0.04...1
Kp
adap
/Kp = 4...35
n
x2
– n
x1
= 0 – 0...(65 – 330) mV
Front panel potentiometer T
N
, additionally
C2
Front panel potentiometer Kp, additionally
R50
R34 and front panel potentiometer ADAP
R38
R40
Drift compensation (offset)
–30...+30 mV (referred to n
set
)
Front potentiometer, drift
Direction of rotation reversal
Cw/ccw for pos. n
set
S2.1
Tachometer adaptation
V
tach.
= 40...15 V/n
rated
Switch S1; additionally R6, R7, R8
Tachometer adjustment
n
actN
= 2.2...0.7
⋅
n
act
(n
act
= 10 V/n
rated
)
Front panel potentiometer tachometer; ad-
ditionally R3 and R10
Speed setpoint adaptation
(speed reduction)
100 %
⋅
11...5V
=
n
actN
or
(only term.56/14)
10 V =
n
actN
1...100
R5
Inhibit I component
Speed controller without
I component
Terminal 6
Limit I component, speed
controller
I component fully effective ... inef-
fective
R52
Current controller
Adaptation, motor/power module
Current actual value normalization
Current controller gain
I
max
= 23...100 %
⋅
I
limit
Kp(I) = 0.5...11.5;
S2.2....S2.5
S2.6...S2.9; additionally R15, if K
p
(I) > 11.5
Current setpoint adaptation
I
max
= 10...0 V
R42
Inhibit I component in current–
controlled operation
Current controller without I compo-
nent
R1
Select current–controlled operation
offline
online via terminal 22
S2.10
R14
Master/slave operation
Up to 5 slave modules
Terminals 258, S2.10, R42, R44
Response threshold, I
2
t limiting,
reduction
6...55 %
⋅
I
limit
R9
Monitoring time, speed controller at
its endstop
26...1200 ms
R54
Monitoring, speed controller at its
endstop
ON
↔
OFF
R32
External current setpoint limiting
(e. g. travel to endstop)
1...100 %
⋅
I
max
Speed controller monitoring OFF
Terminal 96 (variable); R12 (fixed)
Current limiting after the monitoring
time, speed controller at its endstop
1...100 %
⋅
I
max
R2, R32
Current limiting after the I
2
t timer has
expired
Refer to I
2
t limiting in the
Start–up Guide
R2/R32
Torque limiting for setting–up opera-
tion via terminal 112 (NE module)
1...100 %
⋅
I
max
Speed controller monitoring OFF
R12
Electrical weight equalization
I
set, suppl.
= 0...50 %
⋅
I
max
R46/R48
7.1.1 Function overview and settings using the parameter board
Содержание SIMODRIVE 611A
Страница 2: ......
Страница 6: ......
Страница 7: ...SECTION 0 PRELIMINARY INFORMATION 0 7 ...
Страница 8: ......
Страница 17: ...Section 1 611A Analog Feed Drives 1 17 ...
Страница 18: ...1 18 ...
Страница 24: ...1 24 ...
Страница 39: ...1 39 ...
Страница 70: ...1 70 ...
Страница 119: ...1 119 ...
Страница 120: ......
Страница 123: ......
Страница 131: ......
Страница 158: ...1 158 ...
Страница 159: ...1 159 MOUNTING DIMENSIONS ...
Страница 160: ...1 160 ...
Страница 186: ......
Страница 187: ...GENERAL INFORMATION REGARDING AC SERVO MOTORS AL S ...
Страница 188: ......
Страница 225: ...1FT5 AC SERVO MOTOR DESCRIPTIONS 1FT5 ...
Страница 226: ......
Страница 321: ...FEEDBACK DEVICES FOR 1FT5 GE ...
Страница 322: ......