Siemens Energy & Automation
Machine Industry Business
6 / 10 / 96 Rev. - F de
Interface Drawing for :
Date
Revision
Drawn by
611-A Servo
Main Spindle Option ( part of Comfort
Version PCB 6SN1118- 0AA11- 0AA1 )
Built in “Main Spindle Option” Board
PCB P/N:
6SN1114 - 0AA02 - 0AA0
Iact
> I x
Nact
<
Nmin
Nact
< N x
Nact
=
Nset
X322
102
61
75
162 - - - - - - - - - - - - - - - - - - - - - - -
X312
R20
(Ramp Time)
110
108
115
114
216
214
127
126
“Ix” adjustment-R211
“
Nmin
” adjustment-R10
“
Nx
” adjustment-R43
R180
R179
R96 (Main Spindle - Drift [ Balance ] )
R45 (
Kp
- Main Spindle Proportional Gain)
R44 (
Tn
- Main Spindle Integral Gain)
R1 ( Main Spindle - RPM for Pulse Inhibit )
R906 ( Offset / Balance)
R903 ( Amplitude )
R214 ( Speed @ which Current [Torque ]
reduction starts)
R213 ( Current [ Torque ] @ maximum
Speed)
Speed Dependent Current (Torque) Limit
( Sets Constant Power Range )
“
Nact
=
Nset
”
adjustment
- -| |- - -
Term. # 102:
Select Ramp Time
Adjustment Range
(open = 0.01 to 1.1 Sec.’s
(closed = 0.1 to 11 Sec.’s
Term. # 61:
Select Servo / Spindle
operation
(open = Spindle; closed
= Servo [“C” Axis] )
- - - - - - - -| |- - -
- - - - - - - - - - - - - - - - - - - - To I / R Module
From Feed Module
X331
, Terminal “9”
( P24
Ext
. )
1
2
3
4
1
2
3
4
Term. # 75:
Actual Speed output
;
As delivered,
Vout
= 9.45 VDC
@ Motor Rated Speed . For very
accurate requirements,
Vout vs
.
Motor Shaft speed must be
measured ( relationship is linear).
Term. # 162:
Actual Current
or
Actual Power output
( Actual
Power is factory standard )
NOTES:
Main Spindle Mode Adjustments
5
5
Contacts shown “as supplied ”
by the factory. They can be
configured “NO or NC” as
required
Ramp Generator
Speed
Torque
Power
0
0
R214
R213
Fig. 1
[ See Fig. 1]
- - - - - - -
NOTE
: All external
connections are
optional (
ie
; not
required for basic
operation )
Connector
X141
,
Terminal 15 (common)
Special Note
: If the Servo Module contains this “Option”,
it is
imperative that
R4, R5 and C4
(if installed) be removed
from the Parameter Board “6SN1114-0AA01-0AA0”
(see section “H”)
before applying power
.
SECTION I
1-181
Содержание SIMODRIVE 611A
Страница 2: ......
Страница 6: ......
Страница 7: ...SECTION 0 PRELIMINARY INFORMATION 0 7 ...
Страница 8: ......
Страница 17: ...Section 1 611A Analog Feed Drives 1 17 ...
Страница 18: ...1 18 ...
Страница 24: ...1 24 ...
Страница 39: ...1 39 ...
Страница 70: ...1 70 ...
Страница 119: ...1 119 ...
Страница 120: ......
Страница 123: ......
Страница 131: ......
Страница 158: ...1 158 ...
Страница 159: ...1 159 MOUNTING DIMENSIONS ...
Страница 160: ...1 160 ...
Страница 186: ......
Страница 187: ...GENERAL INFORMATION REGARDING AC SERVO MOTORS AL S ...
Страница 188: ......
Страница 225: ...1FT5 AC SERVO MOTOR DESCRIPTIONS 1FT5 ...
Страница 226: ......
Страница 321: ...FEEDBACK DEVICES FOR 1FT5 GE ...
Страница 322: ......