7
02.98
1-82
Siemens AG 1998 All Rights reserved 6SN1197–0AA00 02.98 Edition
SIMODRIVE 611 (PJ)
Interface overview, feed control, standard interface
Table 7-6
Term.
No.
Desig.
Function
Typ
e
1)
Typ. voltage/ limit values
Max. cross–sect.
AS1
AS2
663
9
X321
X321
X321
X321
Checkback signal contact
Relay, start inhibit
Pulse enable
2)
Enable voltage
2)4)
NC
I
O
max. 250 V
AC
/1 A, 30 V
DC
/2 A
+21 ... 3o V
+24 V
1.5 mm
2
1.5 mm
2
1.5 mm
2
1.5 mm
2
56.1
14.1
65.1
9
22.1
9
X331
X331
X331
X331
X331
X331
Speed setpoint
Differential input
3)
Controller enable
2)
Enable voltage
2)4)
Current–controlled operation
2)
Enable voltage
2)4)
I
I
I
O
I
O
0 V ...
±
10 V
+13 ... 30 V
+24 V
+13 ... 30 V
+24 V
1.5 mm
2
1.5 mm
2
1.5 mm
2
1.5 mm
2
1.5 mm
2
1.5 mm
2
56.2
14.2
65.2
9
22.2
9
X332
X332
X332
X332
X332
X332
Speed setpoint
Differential input
3)
Controller enable
2)
Enable voltage
2)4)
Current–controlled operation
2)
Enable voltage
2)4)
I
I
I
O
I
O
0 V ...
±
10 V
+13 ... 30 V
+24 V
+13 ... 30 V
+24 V
1.5 mm
2
1.5 mm
2
1.5 mm
2
1.5 mm
2
1.5 mm
2
1.5 mm
2
X311
Motor encoder, axis 1
X312
Motor encoder, axis 2
X151/351
Equipment bus
_________
1) I=input; O=output; NC=NC contact; NO=NO contact (for signal: Closed=high, open=low)
2) Reference ground terminal 19 NE/monitoring module (it is not permissible to connect this to the general
reference ground, terminal 15)
3) Reference point of the differential input.
The common mode range of the differential input is
24 V with respect to PE potential and
may not be exceeded.
4) Refer to p. 1-40
Note
The drive shuts down and the pulses inhibited after approx. 4 s when the ”heat-
sink overtemperature” switch responds.
The SIMODRIVE 611 feed modules with the control for 1FT5 servomotors are
equipped with an evaluation circuit for the PTC thermistor integrated in the mo-
tor windings.
The motors should be protected from inadmissibly high winding temperatures
with the monitoring combination (response temperature 150
°
C).
As the drive shouldn’t unpredictably intervene in the cutting process, when the
response temperature is reached, this is only signaled to the SIMODRIVE 611,
centrally via terminals 5.1, 5.2, and 5.3 of the rectifier module.
There is no internal system shut down function to protect the motor.The user
must ensure that the motor can thermally recover immediately after the
signal output, by appropriately designing the adaptation control. It may be
necessary to shutdown the motor immediately.
A delay time is not permissible.
If the motor is not thermally monitored, then the complete drive could be
destroyed if an overload condition occurs, or if the drive converter was
over–dimensioned.
Motor PTC thermi-
stor evaluation for
temperature moni-
toring
7.2.2 Interface overview, feed control, standard interface
Содержание SIMODRIVE 611A
Страница 2: ......
Страница 6: ......
Страница 7: ...SECTION 0 PRELIMINARY INFORMATION 0 7 ...
Страница 8: ......
Страница 17: ...Section 1 611A Analog Feed Drives 1 17 ...
Страница 18: ...1 18 ...
Страница 24: ...1 24 ...
Страница 39: ...1 39 ...
Страница 70: ...1 70 ...
Страница 119: ...1 119 ...
Страница 120: ......
Страница 123: ......
Страница 131: ......
Страница 158: ...1 158 ...
Страница 159: ...1 159 MOUNTING DIMENSIONS ...
Страница 160: ...1 160 ...
Страница 186: ......
Страница 187: ...GENERAL INFORMATION REGARDING AC SERVO MOTORS AL S ...
Страница 188: ......
Страница 225: ...1FT5 AC SERVO MOTOR DESCRIPTIONS 1FT5 ...
Страница 226: ......
Страница 321: ...FEEDBACK DEVICES FOR 1FT5 GE ...
Страница 322: ......