11
12
7
6
8
4
3
1
2
5
9
10
Jumpers
Dummy Plug
If the Motor is
disconnected,
the Module
will not fault
if this plug
is installed
- - - - - - - - - - - -
6FX2003-1CF12
- - - - - - - - - - - - - - -
611-A AC Servo
Feed Module
1 ( U )
2 ( V )
6 ( W )
5 ( BR2 )
4 ( BR )
U2
V2
W2
( - )
( + )
Siemens Energy & Automation
Machine Industry Business
6 / 3 / 97 A - 3 de
Interface Drawing for ;
Date
Revision
Drawn by
611-A SERVO, COMFORT VERSION
Wiring of Motor to Drive F/B Cable
Tacho
, Rotor Position & Thermistor
( suggested Wire Size AWG 22 or 24 )
11
12
7
6
8
4
3
1
2
5
9
10
6FX2003-0CE12
( Motor End )
8
15
7
14
1
9
4
6
13
5
2
11
12
6FC9348-7AT
( Drive End )
NOTE
:
Motor to Drive connections
must be exactly as shown !
Connections for
Optional
(G45) Motor Mounted Brake
[24 VDC, + / - 10% - Current range 0.4 to 3.25 Amps
dependent on Motor / Brake size].
If not used, all three (3) wires should be connected to
ground.
Test Points
X
W
M
R Speed Command
T Current Command
NZ Speed Command
Alternate Input
Motor Speed
Motor Current
Reference
Common
“ X “ : Voltage @ Rated Speed ;
= 11 VDC if
Tacho
is rated 16.5 VDC
= 10 VDC if
Tacho
is rated 40 VDC
“ W “ : 10 VDC = ;
Module “ Imax ” as set in Parameter
Board by S2, Switches 2,3,4 & 5
“ M “ : Common reference for all Test Points
“ R ” = Voltage at Terminals
X321
- 56 / 14
(or command inserted at “ NZ ”) .
“ T “ = 10 VDC = ( same as Test Point “ W “ )
“NZ” = Additional input for a speed command
Test Points
Ready / Fault LED Display
Parameter Board Installed
Terminal 65
Enabled
Terminal 663
Enabled
- A - Normal Status Display
- B - Fault Display ( Numeric Display; 1 . . . . 7 )
1 = I
2
T is Active
2 = Rotor Position Detector(or Cable) Fault
3 = Motor
Overtemperature
4 = Tach Monitoring (or Cable) Fault
5 = I
2
T active
and
the Speed Controller is at
Limit ( Drive in Current Limit > 200 ms )
6 = Speed Controller is at Limit ( Drive in
Current Limit > 200 ms, without I
2
T
being active ) .
7 = Speed Controller is at Limit
and
the
Motor Current = 0
Tacho
R
Tacho
S
Tacho
T
Tacho
M
P15(RPG)
RPD R
RPD S
RPD T
M(
Grnd
.)
PTC
PTC
Page 2 / 3
Wiring of Motor to Drive Power Cable
( Wire size dependent on Motor Type )
S2(10 Bit Dip Switch) - Decoding of Switch Settings
Bit 1
= Motor Direction : If
ON
(as shipped),
Motor Rotation CCW
with
+ at Terminal 56
(in reference to 14)
Current Limit as a % of Module Peak Current
Bit 2
=
Bit 3
=
Bit 4
=
Bit 5
=
100 85 68 61 50 46 41 39 36 34 30 29 26 24 23 = %
I
Limit
Current Loop Proportional Gain (
Kp
I)
Bit 6
=
Bit 7
=
Bit 8
=
Bit 9
=
0.5 1 2 2.5 4 4.5 5.5 6 6.5 7.5 8 9.5 11 11.5 =
Kp
I
Bit 10
= If OFF(as delivered), Drive in Velocity Mode.
If ON, Drive in Current(Torque) Mode(Command to 24 & 20)
= Off
= On
NOTE
: For correct grounding, the Drive end Shield
of this cable should be connected to the Connector
Shell or the M5 hole on the top of the Module.
SECTION H
1-179
Содержание SIMODRIVE 611A
Страница 2: ......
Страница 6: ......
Страница 7: ...SECTION 0 PRELIMINARY INFORMATION 0 7 ...
Страница 8: ......
Страница 17: ...Section 1 611A Analog Feed Drives 1 17 ...
Страница 18: ...1 18 ...
Страница 24: ...1 24 ...
Страница 39: ...1 39 ...
Страница 70: ...1 70 ...
Страница 119: ...1 119 ...
Страница 120: ......
Страница 123: ......
Страница 131: ......
Страница 158: ...1 158 ...
Страница 159: ...1 159 MOUNTING DIMENSIONS ...
Страница 160: ...1 160 ...
Страница 186: ......
Страница 187: ...GENERAL INFORMATION REGARDING AC SERVO MOTORS AL S ...
Страница 188: ......
Страница 225: ...1FT5 AC SERVO MOTOR DESCRIPTIONS 1FT5 ...
Страница 226: ......
Страница 321: ...FEEDBACK DEVICES FOR 1FT5 GE ...
Страница 322: ......