Table 1-6 Model GCP5000 (GCE) General Parameters
PARAMETER
VALUES
System Response Time
2 seconds
Relay Drive Outputs (VO):
400 to 1000-ohm load
Minimum Output Current
@ low transmit power
200 mA
Minimum Output Current
@ High transmit power:
400 mA
Surge Protection:
Built-in secondary surge protection for all connections.
Requires external arresters and equalizers on track wires as primary surge
protection.
Surge panels or their electrical equivalent are required.
Refer to paragraph 2.18 for battery and external cable surge protection.
Typical Monitoring and Storage:
Display
SEAR IIi
IO State Changes:
250, 000 minimum
180,000 minimum
Train Moves:
50 minimum
1,800 minimum
Mounting:
The chassis can be wall, rack, or shelf mounted
Temperature Range:
-40 °F to +160 °F (-40 °C to 70 °C)
Table 1-7 Physical Dimension Data
Table 1-7: Physical Dimension and Weight Data
PARAMETER
VALUES
Chassis Dimensions:
Five Track (A80905)
Width:
23.25 In.
(59.055 cm)
Depth:
12.38 In.
(31.445 cm)
Height:
22.15 In.
(56.261 cm)
Chassis Weight:
Empty
Full Module Complement
Five Track (80905)
26.01 lbs (11.7 kg)
48.6 lbs (21.87 kg)
Module Weight:
CPU III (A80903)
1.15 lbs ( 0.51 kg)
PSO (A80428)
1.00 lbs ( 0.45 kg)
RIO (A80413)
1.13 lbs ( 0.51 kg)
SSCC IIIi (A80405)
3.63 lbs (1.63 kg)
Display (A80485-1)
3.88 lbs (1.76 kg)
SEAR IIi (A80410)
5.25 lbs (2.36 kg)