DISPLAY MODULE AND OFFICE CONFIGURATION EDITOR
_________________________________________________________________________________________________________
3-107
SIG-00-22-02 JUNE 2022 (Revised September 2022)
Version: B.1
A Collector site has the following settings.
Table 3-8 Collector Settings
Setting
Description
Office (WAMS) ATCS
Address
ATCS address of the Wayside Alarm Management System software. The
address is a type 2 office address with the following format: 2.RRR.NN.DDDD.
Poll ID
The Genisys protocol poll ID of this site.
WAMS Enabled
Enables or disables communication with the back-office Wayside Alarm
Management System
WAMS XID Enabled
Enables or disables the WAMS XID messages. Typically, this can be left to No
and is not used.
Office Device
The device used to communicate with the office. This setting can be any of the
following:
•
Direct (RS232)
•
MCM (RS232)
•
WAG (Echelon)
•
MCM (Echelon)
•
Dial Modem (RS232)
Modem Phone
Number
If the selected office device is Dial Modem (RS232), the phone number for the
office system must be specified.
Modem Init String
If the selected office device is Dial Modem (RS232), an initialization string for
the modem may be specified.
NOTE: Auto answer for the modem must be disabled. The SEAR IIi handles
phone answering.
Field Device
The device used to communicate with Node SEAR IIi sites in the network. This
setting can be any of the following:
•
VHFC Comm (Echelon)
•
SSR (Spread Spectrum Radio) (RS232)
•
WAG (Echelon)
•
VHF Comm(RS232)
•
None
3.5.2.8.4
CDS-902X
A SEAR IIi configured with a site type of CDS-902X sends alarm messages to the office system
using the Data remote CDS-902X cellular modem. The messages are sent to the office using
the Short Message Service (SMS) or the phone system. There are no additional settings.