BASIC APPLICATION GUIDELINES & PROGRAMMING
_________________________________________________________________________________________________________
5-16
SIG-00-22-02 JUNE 2022 (Revised September 2022)
Version: B.1
Figure 5-10 Out of Service Election and Confirmation Window
5. If the input is not energized the Display will give the following error
Figure 5-11 Out of Service OOS Input not Energized
6. Press Enter when the Out Of Service confirmation window appears
7. RX1 will now be marked as out of service.
8. The system view will show the PSO RX1 as OOS with a blue background
To take the Island (ISL) Out of Service:
1. On the System View window, select the PSO track module by pressing a number 1 to 5
on the keypad. Then press 3 on the keypad to select the Out Of Service option.
2. Select 3] to take Island Out of Service
3. Energize the configured Out of Service input
4. Select 1] when the Out Of Service window appears
5. Press Enter when the Out Of Service confirmation window appears
6. The Out Of Service window will display with a blue background and the statement “Put
RX1 Back in Service” in the window. On the Track View, that PSO will display with a
flashing blue background