3.5.2.11.1
Serial Port
The serial port menu allows the user to configure the serial port connected to the DIAG
connector on the chassis. The DIAG port on the front of the Display module is not user-
configurable.
Figure 3-159 Display Programming Serial Port
3.5.2.11.2
Ethernet Ports
The Display Module has three Ethernet ports. The laptop port should be accessed from the front
of the Display Module. Ethernet ports 1 and 2 should be accessed from the RJ45 connectors on
the GCP Chassis.
NOTE
For Ethernet ports 1 and 2 use the appropriate RJ45 connections on the
GCP5000 chassis. Do not use the RJ45 connections on the front of the
display module, these are only used in a GCP4000.
Laptop Ethernet Port:
This menu allows the user to select between Disabled, DHCP Server, or DHCP Client mode.
The default setting is as a DHCP Server with IP Address 192.168.255.81.