GCP5000 (GCE) INSTALLATION, CALIBRATION AND SYSTEM OPERATIONAL CHECK
_________________________________________________________________________________________________________
6-19
SIG-00-22-02 JUNE 2022 (Revised September 2022)
Version: B.1
6.4.1.2 Types of Tests
Timed Tests
: When the Timed Test is started, the GCP performs the following sequence:
•
Pauses for the programmed Lamp Test Delay time
•
Flashes the lamps for the programmed Lamp Test On-time
•
Turns the lamps off
•
Stops the test.
Repeat Tests
: When the Repeat Test is started, the GCP performs the following sequence:
•
Pauses for the programmed Lamp Test Delay time
•
Flashes the lamps for the programmed Lamp Test On-time
•
Turns the lamps off three times the programmed Lamp Test Delay Time
•
Flashes the lamps for the programmed Lamp Test On-time
•
Turns the lamps off
•
Stops the test.
6.4.1.3 Parameters for Timed Tests
Parameters for each SSCC timed test are set in the fields below the Select Test: field.
The Lamp Test On field designates the duration of the Lamp On test.
Select the
Enter
button to the right of the field to open the Lamp Test On (sec) dialog box. This
Lamp Test On (sec) dialog box allows the test duration timer to be modified.
•
Default value: 15 sec
•
Valid entry range: 15 to 60 seconds
The Lamp Test Delay field designates the time between test selection and test start. Select the
Enter
button to the right of the field to open the Lamp Test Delay (sec) dialog box. This Lamp
Test Delay (sec) dialog box allows the Lamp Test Delay timer to be modified.
•
Default value: 30 sec
•
Valid entry range: 30 to 120 seconds
The Lamp Test Cancel field designates the automatic test termination time following test
initiation. Select the
Enter
button to the right of the field to open the Lamp Test Cancel (min)
dialog box. The Lamp Test Cancel (min) dialog box allows the Lamp Test Cancel timer to be
modified.
•
Default value: 5 min
•
Valid entry range: 1 to 15 minutes
6.4.1.4 Test Status Indications
The status of the SSCC IIIi module appears in the gate display field at the bottom of the window
during tests.
Four status notations appear during operational tests:
•
Off
indicates that the SSCC IIIi lamp drive outputs are off.
•
Ringing
indicates that the SSCC IIIi module bell output is energized.