DISPLAY MODULE AND OFFICE CONFIGURATION EDITOR
_________________________________________________________________________________________________________
3-31
SIG-00-22-02 JUNE 2022 (Revised September 2022)
Version: B.1
Future software revisions will be issued with instructions that describe which module the
software is to be loaded into. Such software instructions may supersede portions of this manual.
The following file types can be uploaded from a USB drive connected to the Display Module:
•
Module Configuration Files (MCF)
•
Module Executable Files (MEF)
•
Configuration Files (PAC)
3.2.1.1 Creating the USB Device File Structure
Uploading or downloading files between the GCP and the USB Device requires that a specific
file structure be created on the USB Device. The system looks for specific file folders to find or
place Application, Executive, Configuration or Report files.
The file structure is as follows for downloads:
•
SAFETRAN
o
DOT-SITENAME
GCP4000
CONFIGURATIONS
•
.PAC FILES
REPORTS
•
<YYYY><MON>
The file structure is as follows for uploads:
•
SAFETRAN
GCP4000
APPLICATIONS
•
.MCF
•
.PAC
EXECUTIVES
•
.MEF
•
.TGZ
PAC files or MCFs to be uploaded should be placed under the GCP4000\Applications.
Executive software to be uploaded should be placed under the GCP4000\Executives.
Downloaded files are placed under the Safetran\DOT-SITENAME\GCP4000 folder.
NOTE
The following section describes uploading and downloading software and
reports from all GCP Modules onto the USB Drive.
NOTE
If a PAC file has been downloaded from the system, and the user wants to
upload it back to the system, it will need to be moved from the
Safetran\DOT-SITENAME\GCP4000 folder to the GCP4000\Applications
folder.