BASIC APPLICATION GUIDELINES & PROGRAMMING
_________________________________________________________________________________________________________
5-15
SIG-00-22-02 JUNE 2022 (Revised September 2022)
Version: B.1
WARNING
INCORRECT DESIGN AND/OR CONFIGURATION OF OUT-OF-
SERVICE INPUTS MAY RESULT IN NO ACTIVATION OF THE
CROSSING WARNING DEVICES.
Then the maintainer can take the PSO out of service as follows:
To take Receiver 1 or 2 Out of Service:
Press Enter when the Out Of Service confirmation window appears
1. On the System View window, select the PSO track module by pressing a number 1 to 5
on the keypad. Then press 3 on the keypad to select the Out Of Service option
Figure 5-8 PSO 1 Options
2. Select 1] or 2] to take RX1 or RX2 Out of Service
Figure 5-9 Select Receiver to Put Out of Service
3. Energize the configured Out of Service input
4. Select 1] when the Out Of Service window appears