DISPLAY MODULE AND OFFICE CONFIGURATION EDITOR
_________________________________________________________________________________________________________
3-13
SIG-00-22-02 JUNE 2022 (Revised September 2022)
Version: B.1
Use the arrow keys on the Display module to select the AND and press
Enter
, this will bring up
the logic diagram that shows what terms contribute to the selected AND output as shown in
Figure 3-17. If a component of the AND is negated in the configuration this is shown with the ‘!’
prefix, so in this case, the NWP is on, so when negated is off, the LED will indicate the state of
!NWP.
Figure 3-17 Logic Details – AND 2 Details
3.1.2.3.3
Logic Details – OR Screen
The Logic Details – OR screen depicts the status of the four ORs (OR 1 – OR 4). Scrolling to
the individual OR and selecting
ENTER
will open a screen depicting the terms used in the OR.
Figure 3-18 Logic Details – OR