DISPLAY MODULE AND OFFICE CONFIGURATION EDITOR
_________________________________________________________________________________________________________
3-98
SIG-00-22-02 JUNE 2022 (Revised September 2022)
Version: B.1
3.5.2.7.1
iLOD Module
When an iLOD module is selected the following parameters are available.
Figure 3-147 Echelon
®
Modules: iLOD
The flash rate in Flashes per Minute sets the message resolution for the lamps being monitored.
This means that if the flash rate varies by as much as this number per minute, then an event
message will go from the iLOD to the SEAR IIi.
The current resolution determines how much of a shift in current will generate a message to the
SEAR IIi
See iLOD, A80271 user guide, SIG-00-03-05 for more details.
3.5.2.7.2
SSCC
The SEAR IIi can be used to monitor an external SSCC module. When SSCC is selected the
parameters shown in Figure 3-148 are available. The user needs to configure the ATCS
address of the SSCC module and the Echelon node (which should correspond to the Subnode
fields in the ATCS Address).