DISPLAY MODULE AND OFFICE CONFIGURATION EDITOR
_________________________________________________________________________________________________________
3-108
SIG-00-22-02 JUNE 2022 (Revised September 2022)
Version: B.1
3.5.2.8.5
Bullhorn/Modbus
A SEAR IIi configured with a site type of Bullhorn/Modbus communicates with the office using a
Bullhorn cellular unit and the Modbus protocol. A Bullhorn/Modbus site has the following
settings.
Table 3-9 Bullhorn/Modbus Settings
Setting
Description
Poll ID
Modbus protocol poll identifier. 1-255
3.5.2.9 Serial Port
The SEAR IIi has two serial ports, the USER port, and the AUX port, these are configured from
the Serial Port tab.
Table 3-10 Serial Port Settings
Setting
Description
Baud Rate
300, 600,1200,2400,4800,9600 (default),19200,38400, 57600
Data Bits
7,8 (default)
Parity
None (default), odd, even
Stop Bits
1 (default), 2
Flow Ctrl
None, Hardware, Radio
Figure 3-156 SEAR Serial Ports: AUX Port