background image

27

200

.2

32

0008

3

JAGA OXYGEN 

REFRESH UNITS

Service manual: OXRE.015 / OXRE.020 / OXRU.015 / OXRU.020

Содержание OXRE.015

Страница 1: ...27200 23200083 JAGA OXYGEN REFRESH UNITS Service manual OXRE 015 OXRE 020 OXRU 015 OXRU 020...

Страница 2: ...o non compliance with the installation cleaning or usage instructions provided by the manufacturer the device is used or handled in an incorrect improper and or irresponsible manner incorrect or non p...

Страница 3: ...or has explained how the device must be operated always supervise children to ensure that they do not play with the device Maintenance maintaining the device is very important to ensure it works corr...

Страница 4: ...top of the OCU Oxygen Control Unit located on the left side of the unit Note for replacement or defective parts contact the installer and consult the general JAGA warranty terms JAGA OXYGEN REFRESH U...

Страница 5: ...EN jaga OXYGEN REFRESH UNIT service manual 97 COMPOSITION OXRE Control panel T water sensor Filter Motor Fan Filter Valve not replaceable OCU CO2 sensor kit OCU...

Страница 6: ...98 OXYGEN REFRESH UNIT service manual jaga OXRU Control panel T water sensor Filter CO2 sensor kit OCU Motor Fan OCU...

Страница 7: ...panel loosen the wall screws by 1 turn so the appliance can be taken down from the wall The t air sensor is located in the appliance centrifuge housing Disconnect the power supply from the unit Unscre...

Страница 8: ...xygen Con trol Unit Remove the sensor by inserting the connector from the inside to the outside through the hole in the housing Open the appliance OCU by sliding it up Disconnect the t air sensor conn...

Страница 9: ...the centrifuge housing and that it is beyond the reach of the fan Connect the new sensor to the white connector on the printed circuit board T Luchtsensor T Luchtsensor Push the new sensor through th...

Страница 10: ...d secure it with 4 screws Reconnect the power supply And lock the OCU with the screw Place the appliance against the wall again Screw the 4 screws so the appliance is fixed Mount the housing around th...

Страница 11: ...NG THE T WATER SENSOR Reference 24800 00030053 05 04 03 02 01 Remove the casing from the device CAUTION If necessary disconnect the coiled cable from the control panel Disconnect the power supply from...

Страница 12: ...f the OCU Connect the new t water sensor to the right red connector on the circuit board in the OCU Place the new sensor through the hole at the bottom of the OCU T Watersensor T Watersensor T Waterse...

Страница 13: ...push the water sensor onto the battery of the low H2O radiator 11 Mount the OCU Reconnect the power supply And lock the OCU with the screw Mount the housing around the unit CAUTION If necessary reconn...

Страница 14: ...ed to be replaced proceed to step 6 Slide the CO2 sensor upwards to remove it from the OCU The CO2 sensor is located on the side of the OCU Oxugen Control Unit REPLACING THE CO2 SENSOR KIT step 11 ste...

Страница 15: ...ount the OCU Disconnect the CO2 sensor connector from the printed circuit board and connect the new sensor in the same place CO2 sensorkit CO2 sensor Water temp sensor Open the appliance OCU by slidin...

Страница 16: ...rvice manual jaga Mount the housing around the unit CAUTION If necessary reconnect the coiled cable to the control panel Reconnect the power supply Slide the new CO2 sensor in the OCU slots provi ded...

Страница 17: ...it will not need replacing go to step 13 If it does need to be replaced proceed to step 6 Remove the appliance control panel Unplug the coiled cable from the control panel Disconnect the power supply...

Страница 18: ...MODE And lock the OCU with the screw Mount the OCU Disconnect the control panel connector and insert the new cable into the appropriate connector on the printed circuit board Open the appliance OCU by...

Страница 19: ...in the desired position and apply pressure for 3 seconds Remove the protective layer from the adhesive zone on the bottom side of the new control panel Connect the coiled cable to the new control pan...

Страница 20: ...EPLACING THE MOTOR FAN Reference MOTOR R3G140 24590 0004002 00 OXRE 015 OXRU 015 OXRE 020 OXRU 020 Remove the casing from the device CAUTION If necessary disconnect the coiled cable from the control p...

Страница 21: ...VAC OUTPUT 24V GND GND Vout AIN Netstekker EU N JDPC 006 L 230V 50Hz Blue Yellow POWER 30W INPUT 110 240VAC OUTPUT 24V GND GND Vout AIN Netstekker EU N JDPC 006 230V 50Hz Ventilator 0 10 V Ventilator...

Страница 22: ...from the motor to the OCU through the provided hole Attach the motor bracket with motor to the ap pliance Fit the new motor to the motor bracket with 4 bolts Pull the cable from the motor through the...

Страница 23: ...ator L 230V 50Hz Blue Yellow POWER 30W INPUT 110 240VAC OUTPUT 24V GND GND Vout AIN Netstekker EU N JDPC 006 Reconnect the 0 10V cables CAUTION ensure this is done in the correct order Blue GND Yellow...

Страница 24: ...n the appliance and secure it with 4 screws Reconnect the power supply Place the appliance against the wall again Screw the 4 screws so the appliance is fixed Mount the housing around the unit CAUTION...

Страница 25: ...ircuit board REPLACING THE CONTROL UNIT OCU Reference JDPC 006 see page 96 Remove the screw above the OCU Oxygen Con trol Unit Open the appliance OCU by sliding it up Remove the casing from the device...

Страница 26: ...POWER 30W INPUT 110 240VAC OUTPUT 24V GND GND Vout AIN N JDPC 006 MODE CO2 sensor E I A B C G H F D Reconnect all cables to the new printed circuit board OCU Ensure the location where the control will...

Страница 27: ...rvice manual 119 Main voltage 230V FAN 0 10V FAN Control CO2 Sensor T Air sensor T Water sensor T Room sensor Valve A B C D E F G H I OXRE 015 C1 C2 C3 C4 C5 OXRE 020 C1 C2 C3 C4 C5 OXRU 015 C1 C2 C3...

Страница 28: ...appliance against the wall again Screw the 4 screws so the appliance is fixed Mount the OCU And lock the OCU with the screw Remove the protective layer from the adhesive zone on the bottom side of th...

Страница 29: ...EN jaga OXYGEN REFRESH UNIT service manual 121 Place the grille back on the appliance Reconnect the power supply Adhere the panel in the desired position and apply pressure for 3 seconds 18 17 16...

Страница 30: ...122 OXYGEN REFRESH UNIT service manual jaga NOTA...

Страница 31: ...EN jaga OXYGEN REFRESH UNIT service manual 123 NOTA...

Страница 32: ...27200 23200083 January 18 2018 2 54 PM Jaga N V Jaga N V Verbindingslaan z n B 3590 Diepenbeek Tel 32 0 11 29 41 11 Fax 32 0 11 32 35 78 info jaga be www jaga be...

Отзывы: